Dental manufacturing is shifting toward digitalization. The National Association of Dental Laboratories’ 2025 survey found that 72% of responding labs use 3D printers, up from 11% in 2014. [1] Dental metal 3D printing stands out in this shift. It builds dental components from cobalt-chromium (CoCr), nickel-chromium (NiCr), and titanium alloys directly from digital files, without the need for traditional wax patterns or casting.
The printer is only one factor. File preparation, material handling, parameter selection, post-processing, and quality control all shape the final result. This guide will explain dental metal 3D printing step by step.
Dental Metal 3D Printing Workflow for Dental Labs
Most dental metal 3D printers use Selective Laser Melting (SLM), a form of laser powder bed fusion technology. A high-energy laser selectively fuses metal powder layer by layer, forming solid components according to a digital design. This process enables labs to manufacture multiple customized components within a single production batch.
Dental metal 3D printing can be divided into 10 steps:
Step 1: Data Reception
The dental 3D printing workflow begins with receiving digital design files. Using data from intraoral or laboratory scans, dental technicians design restorations or appliances in CAD software and export the completed models as STL files. These files represent shapes as a mesh of triangles with no color or texture data.
Before importing the files into build preparation software, technicians should verify:
- The geometry is complete, with no missing surfaces or mesh errors.
- Dimensions, material requirements, and design specifications match the prescription.
- Critical features, including margins and connection areas, are properly defined.
Step 2: Data Nesting & Build Preparation
Next, import the approved STL file into the CAM software. Arrange the parts within the build area, choose an appropriate orientation, set the spacing between components, and generate support structures where required.
Part orientation affects surface quality, support placement, and build time. Supports anchor parts and help manage heat and residual stress. Place them in a position that does not obstruct critical margins or surfaces.
The software then slices the model and generates a build file with the selected material and machine parameters.
Step 3: Powder Loading
Load certified metal powder into the printer. Select the alloy by application:
- CoCr: crowns, bridges, denture frameworks, inlays, posts and cores, and orthodontic appliances. It features high strength, wear resistance, and corrosion resistance.
- NiCr: Used in selected dental restorations and frameworks, depending on alloy composition, biocompatibility, and applicable regulatory requirements. It can offer a cost-effective material option for certain applications.
- Titanium alloys: Commonly used for implant-supported frameworks, abutments, bars, and maxillofacial prostheses, depending on the alloy and validated application. They offer a favorable strength-to-weight ratio, corrosion resistance, and biocompatibility.
Material selection must consider the patient’s allergies and applicable regulatory requirements. Before loading, technicians should check the powder’s specifications, batch documentation, storage conditions, and compatibility with the dental metal 3D printer.
Step 4: Metal 3D Printing Process
Once everything is ready, the printing starts. In an SLM process, the printer spreads a thin powder layer across the build platform. A laser scans the designated areas and melts the particles together. This sequence repeats until the entire component is formed.
The build takes place in a controlled inert atmosphere to limit oxidation and contamination. Argon is commonly used for titanium alloys, while the appropriate shielding gas for other alloys depends on the material and machine specifications. Laser power, layer thickness, scan speed, hatch spacing, and gas flow must follow the qualified parameter set.
Step 5: Heat Treatment
After printing, the build may undergo a controlled heat treatment, depending on the material, component geometry, and qualified process requirements. Thermal treatment can relieve residual stress created by repeated laser heating and cooling, helping reduce distortion when parts are removed from the build plate.
Step 6: Cutting from Build Plate
Once the required thermal cycle is complete and the assembly has cooled, separate the printed parts from the build plate. Depending on the material, geometry, and available equipment, labs may use a band saw, cutting tool, or wire.
Avoid excessive heat and force, which can damage thin sections or distort delicate components.
Step 7: Support Removal
Supports are necessary structures that maintain part shape during printing. Removal is mainly manual with pliers and cutters. The principle is to cut at the connection point between support and part, not to snap from the support base, which tends to leave pits on the part surface.
Step 8: Grinding
Remove support connection marks and surface irregularities while preserving the original design geometry and critical margins. The cervical margin of crowns and bridges and the clasp tips of removable frameworks usually have minor rounding or burrs after printing. Carefully finish the affected areas to remove burrs and surface irregularities without altering the designed marginal geometry or critical dimensions.
Step 9: Polishing
Surface roughness of dental metal parts directly affects plaque accumulation and patient comfort. Polishing improves surface smoothness and appearance.
Plasma polishing is a process suited to complex geometries: plasma discharge in an electrolyte removes microscopic protrusions and can treat areas difficult to reach by hand polishing, such as clasp interiors and connector gaps.
After that, printed parts can achieve a mirror-finish surface without affecting accuracy.
Step 10: Final Product
The part is now ready for clinical delivery. It should undergo a final inspection, for example, checking the fit on the plaster model, marginal adaptation, the retention force of clasps, and the occlusal areas. Once the required checks are completed, the dental component can be delivered.
Riton Supports the Dental Metal 3D Printing Workflow
Riton is a dental 3D printing company founded in 1997, supporting each step above with connected equipment, materials, and software. Our products have been exported to more than 80 countries, with partnerships with over 2,000 labs and clinics.
1. Metal 3D Printers
Riton’s dental metal 3D printer range includes the MLAB, the MCUBE, the M-150 Series, and the M-200D. Each metal laser 3D printer in the range uses SLM technology and delivers micron-level precision.
2. Metal Materials
Riton supplies CoCr, NiCr, and titanium metal printing materials. These powders are developed for dental use, with corrosion resistance, high strength, deformation resistance, and biocompatibility. Applications include implants, crowns, bridges, denture frameworks, inlays, posts and cores, orthodontic appliances, etc.
3. Post-Processing Equipment
Riton matches post-processing equipment to workflow steps:
- Powder separation: Electric Vibrating Screening Machine
- Protective atmosphere: RXT-3000L Nitrogen Generator
- Heat treatment: RT-1300 Furnace
- Cutting: DLY-145W1 Horizontal Electric Band Saw
- Polishing: RT-900 Polishing Machine
- Cleaning: AX1030E Vacuum Cleaner
4. Software Integration
Riton Controller manages the printer. It monitors machine status in real time, tracks printing progress, and supports print recovery after certain interruptions, subject to machine configuration and process conditions. It also records a log for each printed layer, which supports traceability.
The 3D Cloud Design Platform handles design orders. Labs submit requirements online, track order status in real time, and work with Riton’s design team.
Contact Riton to plan a complete dental metal 3D printing workflow.
References
[1] Three Out of Four Labs Now Use 3D Printers: New Results from NADL’s Dental Technology Survey. Available at: https://res.cloudinary.com/carbon3d/image/upload/NADL_REPORT_2025.pdf (Accessed: 4 November 2026)